For clear water, emergency backup usage when power is off or the primary pumps fail |
12 VDC, highly efficient with non-corrosive pump construction |
Control box includes battery burn-out and overcharge protection, self-contained 10 A battery recharger system is a solid state, automatic controller with alarms, light indicators and warning systems |
LCD screen - displays battery voltage along with other helpful information about the system |
Long lasting LED light indicators- AC power - blinks red when power is out, charged - green indicates battery is fully charged, charging - yellow indicates power is going to battery, low battery - red light blinks when below 10.8 V and rapidly blinks when below 8.4 V, high water - yellow light will blink when the float is activated and becomes solid after 3 s, alarm off - yellow light indicates the buzzer is currently silenced |
Highly efficient pump with non corrosive construction |
Alarms to indicate high water, reverse polarity, low battery, all systems are fully solid state automatic controllers with alarms, light indicators and have warning systems |
Reliable low voltage float switch, battery case will fit all group size 27 marine batteries |
Battery case constructed from non-corrodible polyethylene |
Furnished with all required fitting, internal check valve in the discharge and includes an additional heavy-duty check valve adaptable to 1-1/4 or 1-1/2 in pipe |
Primary sump pump must be already installed or ordered separately for new installation |
Buttons scroll, display information on the system such as DC pump cycles and power outages, alarm reset, press to reset alarms, press and hold for three seconds for 24 hr buzzer silence |
Auxiliary alarm contact set of dry contacts allows system to connect to home security systems, auto dialers etc |
Battery case - included battery case will accommodate maximum battery dimensions of 13 in L x 7-1/2 in W x 9-1/2 in H and fits all group size 27, 29 and 31 batteries |
Charger uses the latest switch mode technology available, allows for an extremely efficient charger in a compact design, satisfies the rigid California battery Council standards |
Battery life - estimated life of a fully charged (175 min reserve capacity) battery when the pump is operating continuously is approximately 7.5 hr |
Most backup systems require intermittent pump operation, system will provide protection for extended periods of time dependent upon stop-start requirements |
Pump performance is based on the use of a fully charged 12 VDC, (200 min reserve capacity) deep cycle battery with no deficiency and less than two years old |
Minimum battery requirements deep cycle, size 27, 175 min reserve capacity |
18 in Dia x 24 in D minimum pit size |