MITSUBISHI PUZ-A30NHA7 HEAT PUMP OUTDOOR 30K BTU HEAT PUMP 1:1 USE W/GEN-7 INDOOR ONLY 3/8" X 5/8" LINESET NOT INCLUDED R410A, 208/230/1
-
Color:
Munsell 3Y 7.8/1/1
-
Compressor Type:
Variable Speed Inverter Driven
-
COP Rating:
3.81
-
Dimensions:
37-13/32 in W x 13 + 1-3/16 in D x 37-1/8 in H
-
Discharge Line Size:
3/8 in Flared
-
Flow Rate:
1940 cfm
-
Fuse Size:
25 a
-
Maximum Piping Length:
165 ft
-
Mounting Type:
Wall
-
Series:
P Series
-
Sound Level:
47 dBA Cooling/48 dBA Heating
-
Suction Line Size:
5/8 in Flared
-
Temperature Rating:
0 to 115 deg F DB Cooling/-4 to 70 deg F DB Heating
-
Type:
1-Zone Standard
-
Heating Capacity:
32000 btu/hr
-
Cooling Capacity:
30000 btu/hr
-
Power Source:
208/230 VAC, 19 A, 1 ph, 60 Hz
-
SEER Rating:
19.8
-
EER Rating:
9.5
-
Domestic/Import:
Import
-
HSPF Rating:
9.9
-
Refrigerant Type:
R-410A
Mitsubishi Electric Heat Pump System Outdoor Unit, 1-Zone Standard, Series: P Series, 32000 Btu/hr Heating, 30000 Btu/hr Cooling, 208/230 VAC, 19 A, 1 ph, 60 Hz Power Source, 1940 cfm, 9.5 EER, 19.8 SEER, 9.9 HSPF, 3.81 COP, Variable Speed Inverter Driven Compressor, R-410A Refrigerant, 5/8 in Flared Suction Line, 3/8 in Flared Discharge Line, 25 A Fuse, 0 to 115 deg F DB Cooling/-4 to 70 deg F DB Heating, 47 dBA Cooling/48 dBA Heating Sound Level, 165 ft Maximum Piping Length, Wall Mounting, Munsell 3Y 7.8/1/1, 37-13/32 in W x 13 + 1-3/16 in D x 37-1/8 in H Dimensions, Import Domestic/Import