LEONARD ECO-MIX TA-300-LF Emergency Mixing Valve With Internal Cold Water By-Pass, Activates at Temperature 85 deg F, 1/2 in Inlet, Bronze
LEONARD TA-300-LF EMERGENCY LEAD FREE MIXING VALVE FOR EYE/FACE WASH UNIT 1/2" INLETS/OUTLETS
Eyewash & Shower Thermal Protect. Valves
}
LEONARD ECO-MIX TA-300-LF Emergency Mixing Valve With Internal Cold Water By-Pass, Activates at Temperature 85 deg F, 1/2 in Inlet, Bronze
3332037
Product ID:3332037
Famous Supply
-
Finish:
Rough Bronze
-
Inlet Size:
1/2 in
-
Material:
Bronze
DURA-trol® solid bimetal thermostat directly linked to valve porting to control the intake of hot and cold water and compensate for supply temperature and pressure fluctuations. DURA-trol is highly responsive and cannot be damaged by extremes in temperature. Thermostatic Mixing Valve can be set to the correct temperature for the application. Locking type temperature regulator to prevent accidental movement set for 85 deg F (29 deg C), Recommended Hot Inlet Temperature 140 deg F. Mixing valve will close down on failure of cold water supply, Mixing Valve with special internal cold water bypass capable of 4 GPM (15 l/min) at 30 PSI (2.1 Bar) upon failure of hot water supply. Adjustable high temperature limit stop set for 90 deg F (32 deg C), Full 1/2 in top or bottom inlets and 1/2 in top outlet, Integral wall support, Dial thermometer (range 0 to 140 deg F, -10 to 60 deg C), Rough bronze finish. Union angle checkstops on inlets.
-
Features
-
Standards & Approvals
-
Application
DURA-trol® solid bi-metal thermostatic control |
Locked temperature regulator set for 85 deg F |
High temperature limit stop set for 90 deg F |
Internal cold water bypass on failure of hot water supply standard on all models |
Provide tepid water to eyewash or eye/face wash unit |
Performance: On failure of hot water supply, internal cold water by-pass delivers cold water to the emergency fixture, minimum of 4 gpm at 30 psi, on failure of cold water supply, hot water is shut down |
Has an integral wall mounting bracket |
Certified to meet low lead C US requirements of wetted surface area containing less than 0.25% lead by weight |
180 deg F maximum supply temperature |
125 psi maximum supply pressure |
1/2 in outlet |
2 to 9 gpm flow rate |
Dimension: 7 in W x 5 in D x 7 in H |
ANSI/ISEA Z358.1-2014 |
ASSE 1071 |
CSA Certified |
For Single Eyewash or Eye/Face Wash Units |