Woodford RHY2-MS Freezeless Roof Hydrant With Mounting System, 1 in, FNPT, 48-1/2 in OAL

WOODFORD RHY2-1-MS COMMERCIAL FREEZELESS ROOF HYDRANT W/ MOUNTING SYSTEM

Yard Hydrants
Brand: Woodford logo
}

Woodford RHY2-MS Freezeless Roof Hydrant With Mounting System, 1 in, FNPT, 48-1/2 in OAL

3049783 MFG #: RHY2-1-MS Product ID:3049783
Famous Supply
  • Pressure Rating: 100 psi
  • Series: Model RHY2-MS
  • Temperature Rating: 120 deg f
  • Type: Freezeless
  • Nominal Size: 1 in
  • End Style: FNPT
  • Overall Length: 48-1/2 in
The patented Woodford® RHY2-MS is intended for irrigation purposes and to provide water availability on commercial building roofs. Applications include window washing, cleaning of condenser coils, cooling towers and other types of roof equipment. The RHY2 is backflow protected with an ASSE 1052 double check backflow preventer that is field testable. The backflow device does not require removal for drain down. The RHY2 has a built in vent that allows drainage. Valve body of hydrant is drilled and tapped with 1/8 in drain hole which must be piped to a drain location. The RHY2-MS allows for installation flexibility since it is not necessary to install hydrant when the patented Mounting System is bolted to the roof. The Mounting System utilizes a 3 in opening that allows the hydrant to be installed later if desired. All necessary mounting hardware for proper installation on a commercial roof is supplied, including a 2 degree shim for pitch adjustment.
  • Features
  • Warranty
  • Standards & Approvals
  • Application
Rod guide eliminates side pull on rod, reduces wear on packing, packing nut and stem
Adjustable link for easy adjustment and positive lever lock tension
1-piece variable flow plunger with large cushion type seal for longer life is not easily damaged and assures shut-off even when foreign particles are present
Hydrant automatically drains when shut-off even with hose attached
All hydrant repairs can be made from top of unit without removing hydrant
Model 50HF backflow preventer with 3/4 in hose connection
Field testable dual check holds against 125 psi backflow pressure
1 in NPT female inlet connection
1-1/4 in US made galvanized pipe casing
1/8 in NPT drain hole (must be piped to a drain location)
1 Year
ASSE 1052
For window washing, cleaning of condenser coils, cooling towers and other types of roof equipment