Generac RTG16EZA1 Pre-Wired Automatic Transfer Switch With Built-In Load Center, 120/240 VAC, 100 A, 1 Phase, NEMA 1
GENERAC RXG16EZA1 16 CIRCUIT ## PRE-WIRED TRANSFER SWITCH NEMA 1 CUL >>PLEASE USE SUB!<<
Automatic Transfer Switches
Brand:
}
Generac RTG16EZA1 Pre-Wired Automatic Transfer Switch With Built-In Load Center, 120/240 VAC, 100 A, 1 Phase, NEMA 1
3286335
Product ID:3286335
Famous Supply
-
Depth:
6.3 in
-
Height:
26.4 in
-
Material:
Steel
-
Type:
Pre-Wired Automatic
-
Width:
12.6 in
-
Voltage Rating:
120/240
-
Amperage Rating:
100
-
Number of Phases:
1
-
Enclosure Type:
NEMA 1
The Generac pre-wired switch is designed to operate with 8-17kW air-cooled generators. This transfer switch has an integrated load center for picking up the emergency circuits. It is especially useful where the main service is large and only a portion of the building load will be served by the generator. It is available with a built-in 10, 12 or 16-circuit load center to supply only those circuits that are essential during an emergency. All standard and load center transfer switches are CUL Listed and suitable for use in optional standby systems (NEC702).
-
Features
-
Standards & Approvals
All pre-wired switche are housed in a steel NEMA 1 enclosure, with electrostatically applied and baked powder paint |
The heavy-duty generac contactor is a UL recognized device, designed for year of service |
The controller at the generator handle all the timing, sensing and exercising function |
Electrically operated, mechanically-held contact for fast, positive connections |
Rated for all classes of load, 100 percent equipment rated, both inductive and resistive |
2 pole, 240 VAC contactor |
30 millisecond transfer time |
Dual coil (100A) and single coil (50A) design |
Main contact are silver plated or silver alloy to resist welding and sticking |
NEMA 1 (indoor rated) enclosure is standard |
The transfer switch contactor is rated at 240 VAC and is available in a single phase configuration only |
16 circuit switch |
60 Hz rated AC frequency |
10000 A Withstand |
1/0 - #14 lug range |
Open transition load transition type |
Less than 60 percent utility voltage drop-out |
5 second engine warm-up delay |
60 percent for 5 second standby voltage sensor |
Greater than 80 percent utility voltage pickup |
cULus Listed |
ISO 9001:2008 |