if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1)) { this.Model.StructuredPageData = string.Empty; //} }

Standard Capacity Pressure Reducing Valve, 1 in, NPT Union x FNPT End Style

WATTS 0009763 LFN55BM1-U-070 1 INCH LEAD FREE BRASS WATER PRESSURE REDUCING VALVE, NPT UNION X FPT, ADJUST 25-75 PSI, MAX WORK 300 PSI, SET AT 70 PSI

Pressure Reducing Valves }

Standard Capacity Pressure Reducing Valve, 1 in, NPT Union x FNPT End Style

3575447 MFG #: 0009763 Product ID:3575447
Famous Supply
  • Dimensions: 2-1/4 in D
  • Inlet to Outlet Length: 4-1/8 in
  • Media: Water
  • Series: LFN55B-M1
  • Softgoods Material: EPDM
  • Temperature Rating: 180 deg f
  • Top to Inlet Center: 4-9/16 in
  • Trim Material: Elastomer Disc/Thermal Plastic Seat
  • Type: Standard Capacity
  • Nominal Size: 1 in
  • End Style: NPT Union x FNPT
  • Pressure Range: 400 psi
  • Body Material: Brass
  • Domestic/Import: Domestic
WATTS® Pressure Reducing Valve, Standard Capacity, Series: LFN55B-M1, 1 in Nominal, NPT Union x FNPT, 400 psi, 180 deg F, Media: Water, 4-1/8 in Inlet to Outlet Length, 4-9/16 in Top to Inlet Center, Brass Body, Elastomer Disc/Thermal Plastic Seat Trim, EPDM, 2-1/4 in D, Domestic - This 1 in water pressure reducing valve is used in commercial and residential applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. It consists of a lead free brass body construction, FNPT union inlet by FNPT outlet connection, integral stainless steel strainer, thermoplastic seat, brass sealed spring cage for accessible outdoor waterworks or pit installations, and a thermal expansion bypass. The temperature range is 33 to 180 deg F . Suitable for up to 400 psi , the pressure range can be adjusted from 25 to 75 psi . Factory set at 70 psi .
  • Features
  • Warranty
Engineered copper silicon body material
Serviceable in line
Integral stainless steel strainer removable for cleaning
Thermoplastic seat and bronze cage
Sealed spring cage for accessible outdoor or waterworks pit installations
EPDM diaphragm
The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150 psi
A water saving test program concluded that reducing the supply pressure from 80 to 50 psi (551 to 345 kPa) resulted in a water savings of 30%
The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight
Limited