if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1)) { this.Model.StructuredPageData = string.Empty; //} }

Watts 0009635 LFN55B, LFN55BM1-DU Pressure Reducing Valve, 1 in, Double Union FNPT, 25 to 75 psi, Brass Body, Domestic

WATTS 0009635 LFN55BM1-DU 1" WATER PRESSURE REDUCING VALVE DOUBLE UNION 25-75 PSI

Pressure Reducing Valves }

Watts 0009635 LFN55B, LFN55BM1-DU Pressure Reducing Valve, 1 in, Double Union FNPT, 25 to 75 psi, Brass Body, Domestic

3438527 MFG #: 0009635 Product ID:3438527
Famous Supply
  • Inlet to Outlet Length: 5-5/8 in
  • Media: Water
  • Pressure Class: 400 psig
  • Series: LFN55BM1
  • Softgoods Material: Thermoplastic Seat/Reinforced EPDM Diaphragm
  • Temperature Rating: 33 to 180 deg f
  • Trim Material: Stainless Steel
  • Type: Pressure Reducing
  • Nominal Size: 1 in
  • End Style: Double Union FNPT
  • Pressure Range: 25 to 75 psi
  • Flow Rate: Variable dependent on pressure drop gpm
  • Body Material: Lead Free Brass
This 1 in water pressure reducing valve is used in commercial and residential applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. It consists of a lead free brass body construction, double FNPT union inlet and outlet connection, integral stainless steel strainer, thermoplastic seat, bronze sealed spring cage for accessible outdoor waterworks or pit installations and a thermal expansion bypass. The temperature range is 33 to 180 deg F. Suitable for up to 400 psi, the pressure range can be adjusted from 25 to 75 psi with the standard setting at 50 psi.
  • Features
  • Warranty
  • Standards & Approvals
  • Application
Integral stainless steel strainer removable for cleaning
Thermoplastic seat and bronze cage
Serviceable in line
Sealed spring cage on all models for accessible outdoor or pit installations
Bypass feature controls thermal expansion pressure
The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight
A water saving test program concluded that reducing the supply pressure from 80 to 50 psi resulted in a water savings of 30%
The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150 psi
Corrosion-resistant adjusting screw and sealed cage for waterworks pit installations
50 psi standard reduced pressure
25 to 75 psi adjustable reduced pressure range
1 Year
ASSE 1003
ANSI A112.26.2
CSA B356
IAPMO Listed
MIL-V-1814B Type 1
NSF/ANSI 61-G
UPC Listed
PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm.
Commercial and Residential