if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1))
{
this.Model.StructuredPageData = string.Empty;
//}
}
Watts 0009635 LFN55B, LFN55BM1-DU Pressure Reducing Valve, 1 in, Double Union FNPT, 25 to 75 psi, Brass Body, Domestic
WATTS 0009635 LFN55BM1-DU 1" WATER PRESSURE REDUCING VALVE DOUBLE UNION 25-75 PSI
Pressure Reducing Valves
}
Watts 0009635 LFN55B, LFN55BM1-DU Pressure Reducing Valve, 1 in, Double Union FNPT, 25 to 75 psi, Brass Body, Domestic
3438527
MFG #: 0009635
Product ID:3438527
Famous Supply
-
Inlet to Outlet Length:
5-5/8 in
-
Media:
Water
-
Pressure Class:
400 psig
-
Series:
LFN55BM1
-
Softgoods Material:
Thermoplastic Seat/Reinforced EPDM Diaphragm
-
Temperature Rating:
33 to 180 deg f
-
Trim Material:
Stainless Steel
-
Type:
Pressure Reducing
-
Nominal Size:
1 in
-
End Style:
Double Union FNPT
-
Pressure Range:
25 to 75 psi
-
Flow Rate:
Variable dependent on pressure drop gpm
-
Body Material:
Lead Free Brass
This 1 in water pressure reducing valve is used in commercial and residential applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. It consists of a lead free brass body construction, double FNPT union inlet and outlet connection, integral stainless steel strainer, thermoplastic seat, bronze sealed spring cage for accessible outdoor waterworks or pit installations and a thermal expansion bypass. The temperature range is 33 to 180 deg F. Suitable for up to 400 psi, the pressure range can be adjusted from 25 to 75 psi with the standard setting at 50 psi.
-
Features
-
Warranty
-
Standards & Approvals
-
Application
Integral stainless steel strainer removable for cleaning |
Thermoplastic seat and bronze cage |
Serviceable in line |
Sealed spring cage on all models for accessible outdoor or pit installations |
Bypass feature controls thermal expansion pressure |
The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight |
A water saving test program concluded that reducing the supply pressure from 80 to 50 psi resulted in a water savings of 30% |
The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150 psi |
Corrosion-resistant adjusting screw and sealed cage for waterworks pit installations |
50 psi standard reduced pressure |
25 to 75 psi adjustable reduced pressure range |
ASSE 1003 |
ANSI A112.26.2 |
CSA B356 |
IAPMO Listed |
MIL-V-1814B Type 1 |
NSF/ANSI 61-G |
UPC Listed |
PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. |
Commercial and Residential |