if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1)) { this.Model.StructuredPageData = string.Empty; //} }

Watts 0009471 LFN45B, LFN45BM1-U Standard Capacity Pressure Reducing Valve, 1/2 in, NPT Union Inlet x FNPT Outlet, 25 to 75 psi, Copper Silicon Alloy Body, Domestic

WATTS 0009471 LEAD-FREE LFN45BU-M1 1/2" WATER PRESSURE REDUCING VALVE

Pressure Reducing Valves }

Watts 0009471 LFN45B, LFN45BM1-U Standard Capacity Pressure Reducing Valve, 1/2 in, NPT Union Inlet x FNPT Outlet, 25 to 75 psi, Copper Silicon Alloy Body, Domestic

3284601 MFG #: 0009471 Product ID:3284601
Famous Supply
  • Inlet to Outlet Length: 4-1/16 in
  • Media: Water
  • Pressure Class: 400 psig
  • Series: LFN45B
  • Softgoods Material: Thermoplastic Seat/Reinforced EPDM Diaphragm
  • Temperature Rating: 33 to 180 deg f
  • Trim Material: Stainless Steel
  • Type: Pressure Reducing
  • Nominal Size: 1/2 in
  • End Style: NPT Union Inlet x FNPT Outlet
  • Pressure Range: 25 to 75 psi
  • Flow Rate: Variable dependent on pressure drop gpm
  • Body Material: Lead Free Cast Copper Silicon Alloy
This 1/2 in water pressure reducing valve is designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial, industrial and residential applications. The easy maintenance assembly consists of a lead free cast copper silicon alloy construction, NPT threaded union inlet and FNPT outlet connection, stainless steel integral strainer, thermoplastic seat module, thermal expansion bypass and a sealed spring cage for waterworks pit installations. The temperature range is 33 to 180 deg F. Suitable for up to 400 psi, the pressure range can be adjusted from 25 to 75 psi with the standard setting at 50 psi.
  • Features
  • Warranty
  • Standards & Approvals
  • Application
Integral stainless steel strainer removable for cleaning
Serviceable in line
Sealed spring cage on all models for accessible outdoor or pit installations
Bypass feature controls thermal expansion pressure
The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight
A water saving test program concluded that reducing the supply pressure from 80 to 50 psi resulted in a water savings of 30%
The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150 psi
25 to 75 psi adjustable reduced pressure range
Elastomer disc
50 psi standard reduced pressure
1 Year
ASSE 1003
ANSI A112.26.2
CSA B356
IAPMO Listed
NSF/ANSI 61-G
UPC Listed
PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm.
Commercial and Residential