if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1))
{
this.Model.StructuredPageData = string.Empty;
//}
}
Luxaire TM9Y100C16MP11C LX Series 2-Stage Gas Furnace, Natural Gas, 100000 Btu/hr Input, 96000 Btu/hr Output, 96 % AFUE, 1600 cfm, ECM Blower Motor
LUXAIRE TM9Y100C16MP11 95+% AFUE TWO STAGE STD. ECM 100BTU 16CFM
Gas Furnaces
}
Luxaire TM9Y100C16MP11C LX Series 2-Stage Gas Furnace, Natural Gas, 100000 Btu/hr Input, 96000 Btu/hr Output, 96 % AFUE, 1600 cfm, ECM Blower Motor
3364528
MFG #: TM9Y100C16MP11
Product ID:3364528
Famous Supply
-
Connection Size:
1/2 in
-
Dimensions:
21 in L x 29-1/2 in W x 33 in H
-
Fuse Size:
15 a
-
Ignition Type:
Direct
-
Motor HP:
1/2
-
Series:
LX Series
-
Type:
2-Stage
-
Furnace Position:
Multi-Position
-
Low NOX:
No
-
Gas Type:
Natural Gas
-
Input Capacity:
100000 btu/hr
-
Output Capacity:
96000 btu/hr
-
Voltage Rating:
115
-
AFUE Rating:
96
-
Flow Rate:
1600 cfm
-
Motor Type:
Multi-Speed ECM Blower
These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Selkirk Polyflue, Duravent Polypro, & Centrotherm Innoflue polypropylene venting systems.
-
Features
-
Warranty
-
Standards & Approvals
-
Application
50 to 80 deg F rise air temperature |
30 to 60 deg F low fire air temperature rise |
190 deg F maximum outlet temperature |
2-stage heating operation includes two stage gas valve, two stage inducer operation and ECM blower operation |
Adjustable delay timer allows two stage operation with a 1-stage thermostat |
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary |
Compact, easy to install, ideal 33 in H tall cabinet |
ECM drive and continuous fan options for IAQ performance |
20 Years Limited on Heat Exchangers in Residential Applications, 10 Years Limited on Heat Exchangers in Commercial Applications, Standard 5 Years Limited Parts |
AHRI Certified |
CSA Certified |
Design Certified |