Luxaire TM9Y040A10MP11C LX Series 2-Stage Gas Furnace, Natural Gas, 40000 Btu/hr Input, 38000 Btu/hr Output, 96 % AFUE, 1000 cfm, ECM Blower Motor

LUXAIRE TM9Y040A10MP11 95+% AFUE TWO STAGE STD. ECM 040BTU 10CFM

Gas Furnaces }

Luxaire TM9Y040A10MP11C LX Series 2-Stage Gas Furnace, Natural Gas, 40000 Btu/hr Input, 38000 Btu/hr Output, 96 % AFUE, 1000 cfm, ECM Blower Motor

3364520 MFG #: TM9Y040A10MP11 Product ID:3364520
Famous Supply
  • Connection Size: 1/2 in
  • Dimensions: 14-1/2 in L x 29-1/2 in W x 33 in H
  • Fuse Size: 15 a
  • Ignition Type: Direct
  • Motor HP: 1/2
  • Series: LX Series
  • Type: 2-Stage
  • Furnace Position: Multi-Position
  • Low NOX: No
  • Gas Type: Natural Gas
  • Input Capacity: 40000 btu/hr
  • Output Capacity: 38000 btu/hr
  • Voltage Rating: 115
  • AFUE Rating: 96
  • Flow Rate: 1000 cfm
  • Motor Type: Multi-Speed ECM Blower
These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Selkirk Polyflue, Duravent Polypro, & Centrotherm Innoflue polypropylene venting systems.
  • Features
  • Warranty
  • Standards & Approvals
  • Application
25 to 55 deg F high and low fire air temperature rise
190 deg F maximum outlet temperature
2-stage heating operation includes two stage gas valve, two stage inducer operation and ECM blower operation
Adjustable delay timer allows two stage operation with a 1-stage thermostat
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary
Compact, easy to install, ideal 33 in H tall cabinet
ECM drive and continuous fan options for IAQ performance
Easy access to controls to connect power/control wiring
20 Years Limited on Heat Exchangers in Residential Applications, 10 Years Limited on Heat Exchangers in Commercial Applications, Standard 5 Years Limited Parts
AHRI Certified
CSA Certified
Design Certified
Residential Application